电缆桥架安装布线的注意事项
电缆桥架不宜安装在腐蚀性气体管道和热力管道的上方及腐蚀性液体管道的下方,否则应采取防腐、隔热措施。所以平常安装每一步都要按照正确的安装方法。
The cable tray should not be installed above the corrosive gas pipeline and heat pipe and below the corrosive liquid pipeline, otherwise, anti-corrosion and heat insulation measures should be taken. Therefore, the correct installation method should be followed in every step of installation.
电缆桥架中布线需注意:
Attention should be paid to the wiring in cable tray:
1.电缆桥架布线时,电缆不应有黄麻或其他易延燃材料外护层。
1. When cable tray is used for indoor wiring, the cable shall not be provided with jute or other flame retardant materials.
2.在潮湿的场所或防腐蚀地方采用电缆桥架布线时,应根据不同采取相应的防护措施,并宜选用塑料护套电缆。
2. When cable tray is used for wiring in wet places or anti-corrosion places, corresponding protective measures should be taken according to different conditions, and plastic sheathed cables should be selected.
3.电缆桥架安装时的距地高度一般不宜低于2.50m,垂直安装时距地1.80m以下部分应加金属盖板保护,但敷设在电气专用房间(如配电室,电气竖井、技术层等)内时除外。
3. The height of cable tray from the ground should not be less than 2.50M during installation. When installing vertically, the part below 1.80m above the ground should be protected by metal cover plate, except when it is laid in special electrical room (such as distribution room, electrical shaft, technical layer, etc.).
4.电缆桥架水平安装时,宜按荷载曲线选取跨距进行支撑,跨距一般为1.5~3m。垂直敷设时,其固定点间距不宜大于2m。


4. When the cable tray is installed horizontally, the best span should be selected according to the load curve, and the span is generally 1.5-3m. When laying vertically, the spacing between fixed points should not be greater than 2m.
5.几组电缆桥架在同一高度平行安装时,各相邻电缆桥架间应考虑维护、检修距离。
5. When several groups of cable trays are installed in parallel at the same height, the maintenance and overhaul distance between adjacent cable trays shall be considered.
6.在电缆桥架上可以无间距敷设电缆,电缆在桥架内横断面的填充率:电力电缆不应大于40%;控制电缆不应大于50%。
6. The cable can be laid on the cable tray without interval. The filling rate of the cable in the cross section of the cable tray: the power cable should not be greater than 40%; the control cable should not be greater than 50%.
7.下列不同电压,不同用途的电缆,不宜敷设在同一层桥架上:
7. The following cables with different voltages and different uses should not be laid on the same layer of bridge:
相关标签:济南电缆桥架
相关标签:济南电缆桥架
上一篇:山东电缆桥架使用过程中出现短路现象如何解决?
下一篇:电缆桥架对电缆线管理方法功效有哪些?
下一篇:电缆桥架对电缆线管理方法功效有哪些?
相关文章 / Recommended news
- 济南电缆桥架选购指南:热镀锌与热浸锌一字之差,应用场景与天壤之别
- 山东工程人必看!桥架安装验收7大硬标准,少一项都要返工,附详细数据
- 济南厂房福音!大跨距桥架破解3大痛点,加强筋加,安装省一半钱
- 山东工程人警惕!桥架敷线踩这坑必返工,监理当场叫停,国标早有明确规定
- 济南人避坑!桥架≠线槽,90%工程人都搞混,一字之差差千里
- 避坑指南!山东电缆桥架规格别瞎选,偏大浪费偏小隐患大,国标早就定好了
- 济南人必看!铝合金电缆桥架选对厚度,耐用又省心,90%的人选错踩坑
- 山东人必看!电缆桥架不是“铁架子”,藏着建筑用电的密码,90%的人都不懂
- 800kg/m抗压!济南电缆桥架,破解3大工程痛点,工期省30%
- 3种类型+98%散热!山东电缆桥架,选对不踩坑,布线效率翻倍
阳极氧化铝合金桥架
托盘式电缆桥架
梯式电缆桥架
梯式不锈钢电缆桥架
深灰色金属防火电缆桥架